Updated : 04/22/2024
Overview
Wayne, IL has adopted the 2015 International Codes, with amendments, including the 2015 IRC (for One and Two Family Dwellings) and IBC. Wayne, IL Muni. Codes § 8-1-2 (IRC adoption and amendments) and § 8-1-1 (IBC adoption and amendments).
Helpful resources for Wayne, Illinois include the following.
Residential Building Code
Illinois has yet to adopt a statewide residential code. Local laws will control.See PLRB,
Illinois Building Codes for more information on state level codes.
Wayne adopted the 2015 IRC, locally. Note that adoptions usually come with amendments. So, it is important to review those amendments in addition to the unamended model code.
You can find a copy of the model code here.
You can find information about amendments to the model code
here.
Auto Search - beta:
See sterling(Wayne, IL Municipal Code)
...Adoption not found...
See Amlegal(Wayne, IL CHAPTER 1 BUILDING CODES)
...TITLE 8 BUILDING REGULATIONS CHAPTER 1 BUILDING CODES SECTION: 8-1-1 : Building Code 8-1-2 : Residential Code 8-1-2-1 : Pool Code 8-1-3 : Mechanical Code 8-1-4 : Electrical Code 8-1-5 : Plumbing Code 8-1-6 : Schedule Of Fees And Bonds Adopted 8-1-7 : Commercial Building Construction Process 8-1-8 : Penalty...
Drip Edge
Drip Edge: yes
Ice Barrier
Are ice barriers required for Wayne ? Yes
Citation: § 8-1-2
Municipal Code
https://sterlingcodifiers.com/codebook/index.php?book_id=985&chapter_id=83356#s1122530Comments:
Table R301.2(1) Climatic And Geographic Design Criteria (page 29, Information, insert) Insert:
Ground snow load – 30 pounds per square foot.
Wind speed – 90 miles per hour.
Topographic effects – No.
Seismic design category – A.
Damage from weathering – Severe.
Frost line depth – Forty-two (42) inches.
Damage from termites – Moderate to heavy.
Damage from decay – Slight to moderate.
Winter design temperature – -4 degrees F.
Ice barrier shield underlayment required – Yes.
Flood hazards – See current FIRM and FBFM maps.
Air freezing index – 1700 cumulative degree days below 32 degrees F.
Government Officials
Last Name |
First Name |
Title |
E-mail |
Phone |
Note |
Gricus |
Mike |
Building Inspector |
|
630/584-7760 |
|
Comments
Section R313 Automatic Fire Sprinkler Systems (page 67, delete entire section)
Delete: Entire section. Fire sprinkler systems not mandatory.
Commercial Building Code
Wayne adopted the 2015 IBC, locally. Note that adoptions usually come with amendments. So, it is important to review those amendments in addition to the unamended model code.
You can find a copy of the code
here.You can find information about amendments to the model code
here.
Auto Search - beta:
See Amlegal(Wayne, IL Municipal Code)
...Adoption not found...
See sterling(Wayne, IL 8-1-1: BUILDING CODE:)
...8-1-1: building code:A. Adopted: The village of Wayne hereby amends and adopts a building code for control of buildings and structures as herein p...
Existing Buildings
Wayne, IL did not adopt the IEBC, therefore Chapter 34 of the IBC would apply.
Other Building Codes
Wayne, IL also adopted the following codes:
2015 International Swimming Pool and Spa Code. Wayne, IL Muni. Code § 8-1-2-1.
2015 International Mechanical Code. Wayne, IL Muni. Code § 8-1-3.
2014 National Electrical Code (NFPA 70). Wayne, IL Muni. Code § 8-1-4.
2014 Illinois State Plumbing Code. Wayne, IL Muni. Code § 8-1-5.
2015 International Property Maintenance Code. Wayne, IL Muni. Code § 8-2-1.
2015 International Fuel Gas Code. Wayne, IL Muni. Code § 8-6-1.
Illinois Energy Conservation Code. Wayne, IL Muni. Code § 8-7-1.
2015 International Fire Code. Wayne, IL Muni. Code § 8-8-1.