Overview

Torrington, Wyoming, adopted the 2015 International Residential Code, including Appendices E, F, G, H, J, K, L, M, N, R, and S, with amendments. Torrington, WY Muni. Code §15.04.020 (adoption) and §§15.04.030-15.04.380 (amendments). Torrington, Wyoming, adopted the 2015 International Building Code, including Appendix C, E, H, I, and J, with amendments. Torrington, WY Muni. Code §15.04.200 (adoption) and §§15.04.210-15.04.380 (amendments). Torrington, Wyoming, adopted the 2015 International Existing Building Code with amendments. Torrington, WY Muni. Code §15.04.400 (adoption) and §§15.04.410-15.04.440 (amendments). 

Helpful resources for Torrington, Wyoming include the following.

Residential Building Code

Wyoming has yet to adopt a statewide residential code. Local laws will control.See PLRB, Wyoming Building Codes for more information on state level codes.

Torrington adopted the 2015 IRC, locally. Note that adoptions usually come with amendments. So, it is important to review those amendments in addition to the unamended model code.

You can find a copy of the model code here.

You can find information about amendments to the model code here.

Auto Search - beta:

2015 IRC(Torrington, WY Sec. 15.04.010. - Adoption of uniform codes by reference.)

...of the residents of the city: A. 2015 edition of the International Residential Code for One- and Two-Family Dwellings; B. 2015 edition of the International...

Drip Edge

Drip Edge: yes

Ice Barrier

Are ice barriers required for Torrington ? No
Citation: Torrington WY Muni. code sec. 15.04.050
Municipal Code https://library.municode.com/wy/torrington/codes/code_of_ordinances?nodeId=CD_TIT15BUCO_CH15.04UNCOAD_S15.04.050TAR31AMLIGEDECR
Comments:

The adoption of the residential code included an amendment stating that ice barrier underlayment is not required at the eaves.

Table R301.2 (1), "Climatic and Geographic Design Criteria," is amended to read as follows:

Ground snow load = 30 psf (1.44 kN/m2 )

Wind speed = 90 mph (40 m/s) (3-second gust), Exposure category "C"

Seismic design category = Site Class C

Weathering = Severe

Frost line depth = 42"

Termite = none to slight

Decay = none to slight

Winter design temperature = -1° F (-18° degrees C)

Ice shield underlayment required = No

Flood hazards = FIRM Community Panel #560023, December 11, 1985

Air freezing index = 1500

Mean annual temperature = 48.3° F (9.1° C)
 

Torrington, WY Muni. Code §15.04.050

Government Officials
Last Name First Name Title E-mail Phone Note
Estas Dennis Buildings & Grounds Superintendent destes@torringtonwy.gov 3075324213

Comments

Torrington, Wyoming, adopted the 2015 International Residential Code, including Appendices E, F, G, H, J, K, L, M, N, R, and S, with amendments. Torrington, WY Muni. Code §15.04.020 (adoption) and §§15.04.030-15.04.380 (amendments). 

Existing Buildings

Existing buildings, meaning buildings that were built in accordance to code at the time of construction, typically merit extra consideration in a current updated code.

Torrington, Wyoming, adopted Appendix J of the IRC regarding Existing Buildings. 

Torrington, Wyoming, adopted the 2015 International Existing Building Code with amendments. Torrington, WY Muni. Code §15.04.400 (adoption) and §§15.04.410-15.04.440 (amendments).

Commercial Building Code

Torrington adopted the 2015 IBC, locally. Note that adoptions usually come with amendments. So, it is important to review those amendments in addition to the unamended model code.

You can find a copy of the code here.You can find information about amendments to the model code here.

Auto Search - beta:

2015 IBC(Torrington, WY Sec. 15.04.200. - Adoption.)

...The 2015 International Building Code, including appendix chapters C Group U-Agricultural Buildings, E Supplementary Accessibility Requirements, H Signs, I Patio Covers, and J Grading, are adopted by reference and have the same force and effect as though fully set forth in this chapter, except as specifically amended by this chapter. Copies...

Comments

Torrington, Wyoming, adopted the 2015 International Building Code including Appendix C, E, H, I, and J, with amendments. Torrington, WY Muni. Code §15.04.200 (adoption) and §§15.04.210-15.04.380 (amendments).

Existing Buildings

Torrington, Wyoming, adopted the 2015 International Existing Building Code with amendments. Torrington, WY Muni. Code §15.04.400 (adoption) and §§15.04.410-15.04.440 (amendments). Note the state adopted the 2021 IEBC as a state code.

Other Building Codes

Torrington, Wyoming, adopted the 2015 International Sign Code. Torrington, WY Muni. Code §15.04.010

Torrington, Wyoming, adopted the 2015 International Fire Code with amendments. Torrington, WY Muni. Code §15.04.500 (adoption) and §§15.04.510-15.04.680 (amendments). 

Torrington, Wyoming, adopted the 2015 International Energy Conservation Code with amendments. Torrington, WY Muni. Code §15.04.700 (adoption) and §§15.04.710-15.04.720 (amendments). 

Torrington, Wyoming, adopted the 2015 International Plumbing Code with amendments. Torrington, WY Muni. Code §15.08.010 (adoption) and §§15.08.020-15.08.080 (amendments). 

Torrington, Wyoming, adopted the 2015 International Fuel Gas Code with amendments. Torrington, WY Muni. Code §15.08.100 (adoption) and §§15.08.110-15.08.170 (amendments). 

Torrington, Wyoming, adopted the 2015 International Mechanical Code with amendments. Torrington, WY Muni. Code §15.08.200 (adoption) and §§15.08.210-15.08.300 (amendments). 

Torrington, Wyoming, adopted the 2015 National Electrical Code with amendments. Torrington, WY Muni. Code §15.12.010 (adoption) and §§15.12.020-15.12.050 (amendments). 

Torrington, Wyoming, adopted the 1997 Uniform Code for the Abatement of Dangerous Buildings with amendments. Torrington, WY Muni. Code §15.16.100 (adoption) and §§15.16.110-15.16.190 (amendments).