Updated : 04/22/2024
Overview
Stuart, IA has adopted the 2015 International Codes, with amendments, including the 2015 IRC (for One and Two Family Dwellings) and IBC. Stuart, IA Muni. Code § 148.03 (adoptions and amendments).
Helpful resources for Stuart, Iowa include the following.
Residential Building Code
Iowa adopted a model state residential code but it is not in force unless adopted locally.See PLRB,
Iowa Building Codes for more information on state level codes.
Stuart adopted the 2015 IRC, locally. Note that adoptions usually come with amendments. So, it is important to review those amendments in addition to the unamended model code.
You can find a copy of the model code here.
You can find information about amendments to the model code
here.
Auto Search - beta:
No results were located with the automated search.
Drip Edge
Drip Edge: yes
Ice Barrier
Are ice barriers required for Stuart ? Yes
Citation: § 148.03
Municipal Code
https://stuartia.com/wp-content/uploads/2018/10/2016-Full-Code.pdf#page=263Comments:
TABLE R301.2(1) Climatic and Geographic Design Criteria
Ground Snow Load: 30 PSF
Wind Speed MPH: 90
Seismic Design Category: A
Subject to Damage From: Weathering – Severe, Frost Line Depth – 42", Termite – Moderate-Heavy, Decay – Slight-Moderate
Winter Design Temp.: -5º F
Ice Barrier Required: Yes
Flood Hazards: NFIP Adoption – 1982
Air Freezing Index: 1833
Mean Annual Temp,: 48.6º F
Government Officials
Last Name |
First Name |
Title |
E-mail |
Phone |
Note |
Ashour |
Ashraf |
City Administrator |
|
515/523-1455 |
|
Comments
Stuart, IA has adopted the 2015 IRC and appendix Chapters with the deletion of appendices F, L and P. Stuart, IA Muni. Code § 148.03.
Existing Buildings
Existing buildings, meaning buildings that were built in accordance to code at the time of
construction, typically merit extra consideration in a current updated code.
Stuart, IA has adopted the 2015 IRC including appendix J. Stuart, IA Muni. Code § 148.03.
Commercial Building Code
Stuart adopted the 2015 IBC, locally. Note that adoptions usually come with amendments. So, it is important to review those amendments in addition to the unamended model code.
You can find a copy of the code
here.You can find information about amendments to the model code
here.
Auto Search - beta:
No results were located with the automated search.
Existing Buildings
Stuart, IA has adopted the 2015 IEBC. Stuart, IA Muni. Code § 148.03 (adoption and amendments).
Other Building Codes
Stuart IA also adopted the following codes:
2015 International Mechanical Code. Stuart, IA Muni. Code § 148.03 (adoption and amendments).
2015 International Plumbing Code. Stuart, IA Muni. Code § 148.03 (adoption and amendments).
2014 National Electrical Code (NFPA 70). Stuart, IA Muni. Code § 148.03 (adoption and amendments).
2015 International Fire Code. Stuart, IA Muni. Code § 148.03 (adoption and amendments).
2015 International Property Maintenance Code. Stuart, IA Muni. Code § 148.03 (adoption and amendments).
2015 International Energy Conservation Code. Stuart, IA Muni. Code § 148.03 (adoption and amendments).
2015 International Zoning Code. Stuart, IA Muni. Code § 148.03 (adoption and amendments).
2015 International Swimming Pool and Spa Code. Stuart, IA Muni. Code § 148.03 (adoption and amendments).