Home / Building Codes / Minnesota / South St. Paul

South St. Paul, Minnesota Building Codes

Updated : 04/22/2024

Overview

South St. Paul, MN has adopted the following codes:

  • 2015 Minnesota Building Code, based on the 2012 IBC. Minn. R. § 1305.0011
  • 2015 Minnesota Residential Code, based on the 2012 IRC, including Appendix K with amendments. Minn. R. § 1309.0010.
  • 2015 Minnesota Conservation Code for Existing Buildings, based on the 2012 IEBC with amendments. Minn. R. § 1311.0010.
  • 2015 Minnesota Energy Code, based on the 2012 IECC. Minn. R. § 1322.0010 (residential) and Minn. R. § 1323.0010  (commercial).

South St. Paul, MN City Code § 106-23 (a) (Adoption-State Building Code) 

Helpful resources for South St. Paul, Minnesota include the following.

Residential Building Code

Minnesota adopted a statewide mandatory residential code that will control. Authority for local amendments will be limited.See PLRB, Minnesota Building Codes for more information on state level codes.

South St. Paul adopted the 2012 IRC, statewide. Note that adoptions usually come with amendments. So, it is important to review those amendments in addition to the unamended model code.

You can find a copy of the model code here.

You can find information about amendments to the model code here.

Auto Search - beta:

2020 Minnesota Residential Code (2018 IRC)(St. Paul, MN Sec. 33.02. - State building code—Adoption.)

...Minnesota Statutes, sections 16B.59 through 16B.75, the state building code, as adopted pursuant to laws of the state, is hereby adopted by reference. (b) The following appendix is not a mandatory part of the state building code, but is adopted by reference for...

Drip Edge

Drip Edge: no

Ice Barrier

Are ice barriers required for South St. Paul ? Yes
Citation: 106-23 (a)
Municipal Code https://library.municode.com/mn/south_st._paul/codes/code_of_ordinances?nodeId=SPBLADERE_CH106BUBURE_ARTIISTBUCO_DIV1GE
Comments:

The 2015 Minnesota Residential Code adopted the 2012 International Residential Code, with amendments. Minn. R. § 1309.0010.

Drip Edges: Section R905.2.8.5 is deleted in its entirety. See Minn. R. § 1309.0905. See the tables below.

Table R301.2(1) – Ice Barriers are required. Minn. R. § 1309.0301.

Ground Snow Load Wind Speed (MPH) Topographic Seismic Design Category Damage from Weathering Damage from Frost Line Depth
50 lbs 90 YES A Severe 3 feet, 6 inches
Damage from Termite Winter Design Temp Ice Barrier Underlayment Required Flood Hazards Air Freezing Index Mean Annual Temp
Slight to Moderate, Also see Footnote "C"

Summer 88/72 F

Winter -15 F

See Table R403.5.17

YES See Minn R Chapter 1335

3,000

See Table R403.3(2)

41.16 deg
 

Comments

The 2015 Minnesota Residential Code adopted the 2012 International Residential Code, with amendments. Minn. R. § 1309.0010. The city of South St. Paul adopted the 2015 Minnesota Residential Code. South St. Paul, MN City Code § 106-23 (a) (Adoption-State Building Code)  

Existing Buildings

Existing buildings, meaning buildings that were built in accordance to code at the time of construction, typically merit extra consideration in a current updated code.

Any buildings meeting the requirements of the International Residential Code are exempt from the Minnesota Existing Building Code chapter 1311. Minn. R. § 1309.0100.

References to the International Property Maintenance Code do not apply. Minn. R. § 1311.0020.

Commercial Building Code

South St. Paul adopted the 2012 IBC, statewide. Note that adoptions usually come with amendments. So, it is important to review those amendments in addition to the unamended model code.

You can find a copy of the code here.You can find information about amendments to the model code here.

Auto Search - beta:

2020 Minnesota Bldg. Code (2018 IBC)(St. Paul, MN Sec. 33.02. - State building code—Adoption.)

...Minnesota Statutes, sections 16B.59 through 16B.75, the state building code, as adopted pursuant to laws of the state, is hereby adopted by reference. (b) The following appendix is not a mandatory part of the state building code, but is adopted by reference for...

Comments

The 2015 Minnesota Building Code, effective June 2, 2015, Minn. R. § 1305.0011. The city of South St. Paul adopted the 2015 MN State Building Code. South St. Paul, MN City Code § 106-23 (a) (Adoption-State Building Code) 

Existing Buildings

The 2015 Minnesota Conservation Code for Existing Buildings, was adopted by the city. Minn. R. § 1311.0010: South St. Paul, MN City Code § 106-23 (a) (Adoption-State Building Code) 

Other Building Codes

The city adopted the following:

  • 2015 Minnesota Energy Code, based on the 2012 IECC and optional ASHRAE Standard 90.1-2010, with amendments. Minn. R. § 1322.0010 (residential) and Minn. R. § 1323.0010 (commercial).

  • 2015 Minnesota Accessibility Code, based on Chapter 11 of the 2012 IBC and ANSI A117.1-2009, with Minnesota amendments. Minn. R. § 1341.

  • 2015 Minnesota Mechanical Code, based on Chapters 2-15 of the 2012 IMC, with amendments. Minn. R. § 1346.0050.

  • 2015 Minnesota Fuel Gas Code, Chapters 2-8 of the 2012 IFGC, with amendments. Minn. R. § 1346.5050.

  • 2017 Minnesota Electrical Code, based on the National Electrical Code (NFPA 70), 2017 edition. Minn. R. § 1315.0200

  • 2015 Minnesota State Fire Code, based on the 2012 IFC. Minn. R. § 7511.0090

  • 2015 Minnesota Plumbing Code, based on the 2012 Uniform Plumbing Code, with amendments. Minn. R. § 4714.0050.

South St. Paul, MN City Code § 106-23 (a) (Adoption-State Building Code); § 30-41 (Adoption-MN State Fire Code).