Updated : 04/22/2024
Overview
Severance, CO adopts the following codes:
- The International Building Code, 2018 edition, including Appendix Chapter I. Severance, CO Muni. Code § 18-1-10 (adopted) with amendments at § 18-1-30.
- The International Residential Code, 2018 edition, including Appendix Chapters F and H. Severance, CO Muni. Code § 18-2-10 (adopted) with amendments at § 18-2-30.
- The Uniform Code for Building Conservation Code, 1997 edition. Severance, CO Muni. Code § 18-7-10 (adopted).
- The International Property Maintenance Code, 2018 edition. Severance, CO Muni. Code § 18-9-10 (adopted) with amendments at § 18-9-30.
- The International Existing Building Code, 2018 edition. Severance, CO Muni. Code § 18-10-10 (adopted) with amendments at § 18-10-30.
Helpful resources for Severance, Colorado include the following.
Residential Building Code
Colorado has yet to adopt a statewide residential code. Local laws will control.See PLRB,
Colorado Building Codes for more information on state level codes.
Severance adopted the 2018 IRC, locally. Note that adoptions usually come with amendments. So, it is important to review those amendments in addition to the unamended model code.
You can find a copy of the model code here.
You can find information about amendments to the model code
here.
Auto Search - beta:
2018 IRC(Severance, CO Sec. 18-2-10. - Adoption.)
...The International Residential Code, 2018 Edition as published by the International
Code Council, 4051 West Flossmoor Road, Country Club Hills, IL 60478, Chapters 1 through
43 inclusive and Appendix Chapters F and H is hereby adopted by reference as the Town
of Severance Residential Building Code as if fully set out in this [Article] with
the...
Drip Edge
Drip Edge: yes
Ice Barrier
Are ice barriers required for Severance ? Yes
Citation: Severance, CO Muni. Code § 18-2-30.
Municipal Code
https://library.municode.com/co/severance/codes/municipal_code?nodeId=CH18BURE_ART2RECO_S18-2-30AMComments:
Table R301.2 (1)
Climatic and Geographic Design Criteria
Ground Snow Load |
Wind Design |
Seismic Design Category |
Subject to Damage From |
Winter Design Temp |
Ice Barrier Under-
layment Required |
Flood Hazard |
Air Freezing Index |
Mean Annual Temp |
Speed (V) |
Topo-
graphic effects |
Weather-
ing |
Frost Line Depth |
Termite |
30psf |
115 |
No |
B |
Severe |
30 in. |
Slight to Mode-
rate |
1 |
YES |
* |
1,000 |
45°F |
Comments
Severance, CO adopts the International Residential Code, 2018 edition, including Appendix Chapters F and H. Severance, CO Muni. Code § 18-2-10 (adopted) with amendments at § 18-2-30.
Existing Buildings
Existing buildings, meaning buildings that were built in accordance to code at the time of
construction, typically merit extra consideration in a current updated code.
Severance, CO adopts the International Property Maintenance Code, 2018 edition. Severance, CO Muni. Code § 18-9-10 (adopted) with amendments at § 18-9-30.
There is no mention of the adoption of Appendix J of the 2018 IRC.
Commercial Building Code
Severance adopted the 2018 IBC, locally. Note that adoptions usually come with amendments. So, it is important to review those amendments in addition to the unamended model code.
You can find a copy of the code
here.You can find information about amendments to the model code
here.
Auto Search - beta:
2018 IBC(Severance, CO Sec. 18-1-10. - Adoption.)
...The International Building Code, 2018 Edition as published by the International Code
Council, 4051 West Flossmoor Road, Country Club Hills, IL 60478. Chapters 1 through
33 inclusive and Appendix Chapter I, is hereby adopted by reference as the Town of
Severance Building Code as if fully set out in this [Article] with the additions,
deletions...
Comments
Severance, CO adopts the International Building Code, 2018 edition, including Appendix Chapter I. Severance, CO Muni. Code § 18-1-10 (adopted) with amendments at § 18-1-30.
Existing Buildings
Severance, CO adopts the International Existing Building Code, 2018 edition. Severance, CO Muni. Code § 18-10-10 (adopted) with amendments at § 18-10-30.
Other Building Codes
Severance, CO also adopts the following codes:
- The International Mechanical Code, 2018 edition. Severance, CO Muni. Code § 18-3-10 (adopted) with amendments at § 18-3-30.
- The International Plumbing Code, 2018 edition. Severance, CO Muni. Code § 18-4-10 (adopted) with amendments at § 18-4-30.
- The National Electrical Code, 2014 edition or the succeeding edition currently adopted by the State Electrical Board, Division of Professions and Occupations, Department of Regulatory Agencies. Severance, CO Muni. Code § 18-4-40 (adopted) with amendments at § 18-4-50.
- The International Fire Code, 2012 edition, including Appendices B, C, D, H, I, and J. Severance, CO Muni. Code § 18-5-10 (adopted) with amendments at § 18-5-30.
- The International Fuel Gas Code, 2018 edition. Severance, CO Muni. Code § 18-6-10 (adopted) with amendments at § 18-6-30.
- The International Energy Conservation Code, 2018 edition. Severance, CO Muni. Code § 18-8-10 (adopted) with amendments at § 18-8-30.
- The International Swimming Pool and Spa Code, 2018 edition. Severance, CO Muni. Code § 18-12-10 (adopted)