Residential Building Code
Colorado has yet to adopt a statewide residential code. Local laws will control.See PLRB,
Colorado Building Codes for more information on state level codes.
Salida adopted the 2015 IRC, locally. Note that adoptions usually come with amendments. So, it is important to review those amendments in addition to the unamended model code.
You can find a copy of the model code here.
You can find information about amendments to the model code
here.
Auto Search - beta:
2015 IRC(Salida, CO Sec. 18-2-10. - Adoption.)
...Pursuant to Title 31, Article 16, Part 2, C.R.S., there is hereby adopted by reference
Chapters 1 through 44 of the International Residential Code (IRC), 2015 Edition, published
by the International Code Council, Inc., 4051 West Flossmoor Road, Country Club Hills,
IL 60478, to have the same force and effect as if set forth herein in every particular....
Drip Edge
Drip Edge: yes
Ice Barrier
Are ice barriers required for Salida ? Yes
Citation: Salida, CO Muni. Code § 18-2-30.
Municipal Code
https://library.municode.com/co/salida/codes/code_of_ordinances?nodeId=CH18BURE_ARTIIRECO_S18-2-30AMComments:
Table R301.2(1), is amended to read:
Ground Snow Load: In accordance with Snow Load Zone Map and Elevation/Zone Table
Wind Speed: 120 MPH V ult
Topographic Effects: No
Special Wind Region: No
Wind-borne Debris Zone: No
Seismic Design Category: C unless geotechnical study indicates otherwise
Weathering: Severe
Frost Line Depth:
24" below finished grade up to 8,000 feet above sea level
30" below finished grade between 8,001-10,000 feet above sea level
36" below finished grade above 10,000 feet above sea level
Termite: None to slight
Winter Design Temp: 0 degrees
Ice Barrier Underlayment Required: Yes
Flood Hazards: Entered NFIP Program 2/10/87 through Resolution 1987-7, Flood Insurance Study Dated 3/4/87, Panel Numbers all begin with 08015C and are followed by; 0025, 0075, 0100, 0150, 0200, 0300, 0304, 0307, 0308, 0309, 0315, 0328, 0330, 0335, 0340, 0425, 0428, 0429, 0430, 0435, 0445, 0455, 0460, 0465, 0470, 0541, 0542, 0555, 0560, 0562, 0566, 0568, 0569, 0580, 0585, 0588, 0589, 0591, 0592, 0593, 0594, 0611, 0613, 0615, 0625, 0660, 0677, 0680 all followed by suffix D (48 panels plus index)
Air Freezing Index: 1,500
Mean Annual Temp: 40 degrees Fahrenheit
Comments
Salida, CO adopts the International Residential Code, 2015 edition. Salida, CO Muni. Code § 18-2-10 (adopted) with amendments at § 18-2-30.
Existing Buildings
Existing buildings, meaning buildings that were built in accordance to code at the time of
construction, typically merit extra consideration in a current updated code.
Salida, CO adopts the International Property Maintenance Code, 2015 edition. Salida, CO Muni. Code § 18-14-10 (adopted) with amendments at § 18-14-30.
There is no mention of the adoption of Appendix J of the 2015 IRC.
Commercial Building Code
Salida adopted the 2015 IBC, locally. Note that adoptions usually come with amendments. So, it is important to review those amendments in addition to the unamended model code.
You can find a copy of the code
here.You can find information about amendments to the model code
here.
Auto Search - beta:
2015 IBC(Salida, CO Sec. 18-1-10. - Adoption.)
...Pursuant to Title 31, Article 16, Part 2, C.R.S., there is hereby adopted by reference Chapters 1 through 35 and Appendix
I of the International Building Code (IBC), 2015 Edition, published by the International
Code Council, Inc., 4051 West Flossmoor Road, Country Club Hills, IL 60478, to have
the same force and effect as if set forth herein in every particular...
Comments
Salida, CO adopts the International Building Code, 2015 edition, including Appendix I. Salida, CO Muni. Code § 18-1-10 (adopted) with amendments at § 18-1-30.
Existing Buildings
Salida, CO adopts the International Existing Building Code, 2015 edition, including Appendix B. Salida, CO Muni. Code § 18-4-10 (adopted) with amendments at § 18-4-30.