Updated : 08/27/2024
Overview
Rosemont, Illinois, adopted the 2006 International Residential Code (IRC), including appendices A, B, C, D, F, G, I, J, K, M, N, O, Q, with amendments. Rosemont, IL, Muni. Code § 11-2-3 (adoption and amendments). Rosemont, Illinois, adopted the 2006 International Building Code (IBC), including appendices E, G, H, K5, K6, K7, K9 and K10, with amendments. Rosemont, IL, Muni. Code § 11-2-2 (adoption and amendments). For Rosemont, Illinois, no local adoption and no local amendments of an existing building code were located.
Helpful resources for Rosemont, Illinois include the following.
Residential Building Code
Illinois has yet to adopt a statewide residential code. Local laws will control.See PLRB,
Illinois Building Codes for more information on state level codes.
Rosemont adopted the 2006 IRC, locally. Note that adoptions usually come with amendments. So, it is important to review those amendments in addition to the unamended model code.
You can find a copy of the model code here.
You can find information about the adoption without amendment to the model code
here.
Auto Search - beta:
See Amlegal(Rosemont, IL CHAPTER 2: BUILDING CODES)
...CHAPTER 2: BUILDING CODES Section 11-2-1 : Adoption Of Codes By Reference 11-2-2 : Building Code 11-2-3 : Residential Code 11-2-4 : Property Maintenance Code 11-2-5 : Electrical Code 11-2-6 : Mechanical Code 11-2-7 : Energy Code 11-2-8 : Fire Code 11-2-9 : Boiler And Pressure Vessel Code 11-2-10 : Enforcement And Penalty...
Drip Edge
Drip Edge: no
Ice Barrier
Are ice barriers required for Rosemont ? Yes
Citation: Rosemont, IL, Muni. Code § 11-2-3 (amendments).
Municipal Code
https://codelibrary.amlegal.com/codes/rosemontil/latest/rosemont_il/0-0-0-9670Comments:
1. |
Insert “25 pounds per square foo”” below the column titled “Ground Snow Load”. |
2. |
Insert “90 miles per hour” below the column titled “Wind Speed”. |
3. |
Insert “B” below the column titled “Seismic Design Category”. |
4. |
Insert “Severe” below the column titled “Weathering”. |
5. |
Insert “42 inches” below the column titled “Frost Line Depth”. |
6. |
Insert “Moderate to heavy” below the column titled “Termite”. |
7. |
Insert “-4 degrees Fahrenheit” below the column titled “Winter Design Temp”. |
8. |
Insert “Yes” below the column titled “Ice Barrier Underlayment Required”. |
9. |
Insert “See applicable Village Code” below the column titled “Flood Hazards”. |
10. |
Insert “1700″ below the column titled “Air Freezing Index”. |
11. |
Insert “47 Degrees Fahrenheit” below the column titled “Mean Annual Temperature”. |
Government Officials
Last Name |
First Name |
Title |
E-mail |
Phone |
Note |
Holtman |
Ronald |
Director of Building & Code Enforcement |
holtmanr@villageofrosemont.org |
847/825-4404 |
|
Lawlor |
Kathryn |
Administrative Assistant |
klawler@villageofrosemont.org |
847-993-8309 |
|
Comments
Rosemont, Illinois, adopted the 2006 International Residential Code (IRC), including appendices A, B, C, D, F, G, I, J, K, M, N, O, Q, with amendments. Rosemont, IL, Muni. Code § 11-2-3 (adoption and amendments).
Existing Buildings
Existing buildings, meaning buildings that were built in accordance to code at the time of
construction, typically merit extra consideration in a current updated code.
Please refer to appendix J of the adopted 2006 IRC.
For Rosemont, Illinois, no local adoption and no local amendments of an existing building code were located.
Commercial Building Code
Rosemont adopted the 2006 IBC, locally . Note that adoptions usually come with amendments. So, it is important to review those amendments in addition to the unamended model code.
You can find a copy of the code
here.You can find information about the adoption without amendment to the model code
here.
Auto Search - beta:
See Amlegal(Rosemont, IL Municipal Code)
...Adoption not found...
Comments
Rosemont, Illinois, adopted the 2006 International Building Code (IBC), including appendices E, G, H, K5, K6, K7, K9 and K10, with amendments.
Existing Buildings
For Rosemont, Illinois, no local adoption and no local amendments of an existing building code were located.
Other Building Codes
Rosemont, Illinois, adopted the 2006 International Property Maintenance Code (IPMC), with amendments. Rosemont, IL, Muni. Code § 11-2-4 (adoption and amendments).
Rosemont, Illinois, adopted the 2008 National Electrical Code (NFPA 70), with amendments. Rosemont, IL, Muni. Code § 11-2-5 (adoption and amendments).
Rosemont, Illinois, adopted the 2006 International Mechanical Code (IMC), with amendments. Rosemont, IL, Muni. § 11-2-6 (adoption and amendments).
Rosemont, Illinois, adopted the 2012 International Energy Code. Rosemont, IL, Muni. Code § 11-2-7 (adoption).
Rosemont, Illinois, adopted the 2006 International Fire Code (IFC), with amendments. Rosemont, IL, Muni. Code § 11-2-8 (amendments).
Current Illinois State Plumbing Code. Rosemont, IL, Muni. Code § 11-3-1 (amendments).