Updated : 04/22/2024
Overview
Norwalk, IA has adopted the 2012 International Codes, with amendments, including the 2012 IRC and IBC. Norwalk, IA Muni. Codes § 160.01 (IRC adoption), § 160.02 (IRC amendments), § 155.01 (IBC adoption) and § 155.02 (IBC amendments).
Helpful resources for Norwalk, Iowa include the following.
Residential Building Code
Iowa adopted a model state residential code but it is not in force unless adopted locally.See PLRB,
Iowa Building Codes for more information on state level codes.
Norwalk adopted the 2012 IRC, locally. Note that adoptions usually come with amendments. So, it is important to review those amendments in addition to the unamended model code.
You can find a copy of the model code here.
You can find information about amendments to the model code
here.
Auto Search - beta:
2015 IRC with Iowa amendments(Norwalk, IA 155.02 ADOPTION OF BUILDING CODE.)
...Pursuant to published notice as required by law, the International Building Code 2018 Edition, published by the International Code Council, Inc., is adopted in full except for such portions as may be hereinafter deleted, modified or amended....
Drip Edge
Drip Edge: yes
Ice Barrier
Are ice barriers required for Norwalk ? Yes
Citation: § 160.02
Municipal Code
https://library.amlegal.com/nxt/gateway.dll/Iowa/norwalk_ia/codeofordinancesofthecityofnorwalkiowa/chapter160residentialcode?f=templates$fn=default.htm$3.0$vid=amlegal:norwalk_ia$anc=JD_160.02Comments:
TABLE R301.2(1) CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA
Ground Snow Load
|
Wind Design
|
Seismic Design Category
|
Subject To Damage From
|
Winter Design Temp
|
Ice Barrier Underlayment Required
|
Flood Hazards
|
Air Freezing Index
|
Mean Annual Temp
|
Speed (mph)
|
Topographic effects
|
Weathering
|
Frost line depth
|
Termite
|
30
|
90
|
No
|
A
|
Severe
|
42”
|
Mod/Heavy
|
-5 F
|
Yes
|
1/21/1993
2/19/2009
|
1833
|
48.6
|
Comments
Norwalk, IA has adopted the 2012 IRC including appendices F, G and M. Norwalk, IA Muni. Code § 160.01.
Section R313.1 Townhouse Automatic Fire Sprinkler Systems, of the International Residential code, 2012 Edition, shall be amended by deleting said subsection and inserting the following in lieu thereof. Exceptions remain unchanged.
Section R313.1 Townhouse Automatic Fire Sprinkler Systems. An automatic residential fire sprinkler system shall be installed in townhouses containing more than 8,000 square feet.
Norwalk, IA Muni. Code § 160.02.
Commercial Building Code
Norwalk adopted the 2012 IBC, locally . Note that adoptions usually come with amendments. So, it is important to review those amendments in addition to the unamended model code.
You can find a copy of the code
here.You can find information about amendments to the model code
here.
Auto Search - beta:
2015 IBC with Iowa amendments(Norwalk, IA Municipal Code)
...Adoption not found...
Existing Buildings
Norwalk, IA did not adopt the IEBC, therefore Chapter 34 of the IBC would apply.
Other Building Codes
Norwalk, IA also adopted the following codes:
2012 International Plumbing Code. Norwalk, IA Muni. Codes § 156.01 (adoption) and § 156.02 (amendments).
2012 International Mechanical Code. Norwalk, IA Muni. Codes § 157.01 (adoption) and § 157.02 (amendments).
2011 National Electrical Code (NFPA 70). Norwalk, IA Muni. Codes § 158.01 (adoption) and § 158.02 (amendments).
2012 International Fire Code. Norwalk, IA Muni. Codes § 159.01 (adoption) and § 159.02 (amendments).
2012 International Fuel Gas Code. Norwalk, IA Muni. Codes § 161.01 (adoption) and § 161.02 (amendments).