Updated : 06/26/2024
Overview
Nolensville, Tennessee, adopted the 2018 International Residential Code (IRC), including Appendices F, H, I, J, and T, with amendments. TN ADC 0780-02-23-.02(1)(a) and Nolensville, TN, Muni. Code § 12-401 (adoption and amendments). Nolensville, Tennessee, adopted the 2018 International Building Codes (IBC), including Appendices A, B, and C. TN ADC 0780-02-02-.01(1)(a), Nolensville, TN, Muni. Code § 12-101 (adoption), and §§ 12-101 through 12-106 (amendments). Nolensville, Tennessee, adopted the 2018 International Existing Building Code (IEBC). TN ADC 0780-02-02-.01(1)(h) and Nolensville, TN, Muni. Code § 12-701 (adoption).
Helpful resources for Nolensville, Tennessee include the following.
Residential Building Code
Tennessee adopted a statewide mandatory residential code that will control; however, local governments are free to make laws more strict (with some limitations).See PLRB,
Tennessee Building Codes for more information on state level codes.
Nolensville adopted the 2018 IRC, locally. Note that adoptions usually come with amendments. So, it is important to review those amendments in addition to the unamended model code.
You can find a copy of the model code here.
You can find information about amendments to the model code
here.
Auto Search - beta:
Drip Edge
Drip Edge: Yes
Ice Barrier
Are ice barriers required for Nolensville ? No
Citation: § 12-401(4)
Municipal Code
https://www.mtas.tennessee.edu/system/files/codes/Nolensville_t12.pdf#Page=6Comments:
The adoption of the residential code included an amendment stating that ice barrier underlayment is not required at the eaves. Table R301.2(1) add the following:
Ground Snow Load “10 lbs”
Wind Design Speed “115”
Topographic Effects “No”
Special Wind Region “No”
Windborne Debris Zone “No”
Seismic Design Category “B”
Weathering “Severe”
Frost Line Depth “12”
Termite “Moderate to Heavy”
Winter Design Temperature “14 F”
Ice Barrier Underlayment Required “No”
Flood Hazards “as shown on the latest adopted FEMA FIRM”
Air Freezing Index “366”
Mean Annual Temp “57 degrees F”
Nolensville, TN, Muni. Code § 12-401(4).
Government Officials
Last Name |
First Name |
Title |
E-mail |
Phone |
Note |
McCoy |
Bennie |
Building Official |
bmccoy@nolensvilletn.gov |
615/776-6692 |
|
King |
Hope |
Codes Assistant |
mking@nolensvilletn.gov |
615-776-6686 |
|
Comments
Nolensville, Tennessee, adopted the 2018 International Residential Code (IRC), including Appendices F, H, I, J, and T, with amendments. TN ADC 0780-02-23-.02(1)(a) and Nolensville, TN, Muni. Code § 12-401 (adoption and amendments).
For information regarding automatic fire sprinkler systems, see Nolensville, TN, Muni. Code § 7-301 and § 12-401(6).
Existing Buildings
Existing buildings, meaning buildings that were built in accordance to code at the time of
construction, typically merit extra consideration in a current updated code.
Nolensville, TN, adopted the Appendix J of the adopted 2018 IRC. Nolensville, TN, Muni. Code § 12-401.
Nolensville, Tennessee, adopted the 2018 International Existing Building Code (IEBC). TN ADC 0780-02-02-.01(1)(h) and Nolensville, TN, Muni. Code § 12-701 (adoption).
Commercial Building Code
Nolensville adopted the 2018 IBC, locally. Note that adoptions usually come with amendments. So, it is important to review those amendments in addition to the unamended model code.
You can find a copy of the code
here.You can find information about the adoption without amendment to the model code
here.
Auto Search - beta:
Comments
Nolensville, Tennessee, adopted the 2018 International Building Codes (IBC), including Appendices A, B, and C. TN ADC 0780-02-02-.01(1)(a), Nolensville, TN, Muni. Code § 12-101 (adoption), and §§ 12-101 through 12-106 (amendments).
Existing Buildings
Nolensville, Tennessee, adopted the 2018 International Existing Building Code (IEBC). TN ADC 0780-02-02-.01(1)(h) and Nolensville, TN, Muni. Code § 12-701 (adoption).
Other Building Codes
Nolensville, Tennessee, adopted the 2018 International Fire Code (IFC), including all Appendices. Nolensville, TN, Muni. Code § 7-101 (adoption) and TN ADC 0780-02-02-.01.
Nolensville, Tennessee, adopted the 2018 Life Safety Code (NFPA 101), with amendments. Tenn. Comp. R. and Regs. 0780-02-02-.01(i), Nolensville, TN, Muni. Code § 7-201 (adoption), and §§ 7-202 through 7-209 (amendments).
Nolensville, Tennessee, adopted the 2018 International Plumbing Code (IPC), with amendments. Nolensville, TN, Muni. Code § 12-201 (adoption and amendments) and TN ADC 0780-02-02-.01.
Nolensville, Tennessee, adopted the 2018 International Fuel Gas Code (IFGC), with amendments. Nolensville, TN, Muni. Code § 12-301 (adoption and amendments) and TN ADC 0780-02-02-.01.
Nolensville, Tennessee, adopted the 2018 International Swimming Pool and Spa Code (ISPSC), including Appendices A and B, with amendments. Nolensville, TN, Muni. Code § 12-501 (adoption and amendments).
Nolensville, Tennessee, adopted the 2018 International Mechanical Code (IMC), with amendments. Nolensville, TN, Muni. Code § 12-601 (adoption and amendments) and TN ADC 0780-02-02-.01.
Nolensville, Tennessee, adopted the 2018 International Energy Conservation Code (IECC), including all Appendices, with amendments. TN ADC 0780-02-23-.02, Nolensville, TN, Muni. Code § 12-801 (adoption), and § 12-802 (amendments).
Nolensville, Tennessee, adopted the 2018 International Property Maintenance Code (IPMC), including Appendix A and B, with amendments. Nolensville, TN, Muni. Code § 12-901 (adoption and amendments) and TN ADC 0780-02-02-.01.
The state adopted a minimum electrical standard based on the 2017 National Electrical Code (NEC). Tenn. Comp. R. and Regs. 0780-02-01-.02. No local jurisdiction is authorized to adopt less stringent regulations. Tenn. Comp. R. and Regs. 0780-02-01-.17.