Updated : 04/22/2024
Overview
New Castle, CO adopts the following codes:
- The International Building Code, 2015 edition, including Appendices B, G, I, and J. New Castle, CO Muni. Code § 15.08.010 (adopted) with amendments at § 15.08.020.
- The International Residential Code, 2015 edition, including Appendices H, J, and S. New Castle, CO Muni. Code § 15.10.010 (adopted) with amendments at § 15.10.020.
- The International Existing Building Code, 2015 edition, including all appendices. New Castle, CO Muni. Code § 15.18.010 (adopted) with amendments at § 15.18.020.
- The Uniform Code for the Abatement of Dangerous Buildings, 1994 edition. New Castle, CO Muni. Code § 15.20.010 (adopted).
Helpful resources for New Castle, Colorado include the following.
Residential Building Code
Colorado has yet to adopt a statewide residential code. Local laws will control.See PLRB,
Colorado Building Codes for more information on state level codes.
New Castle adopted the 2015 IRC, locally. Note that adoptions usually come with amendments. So, it is important to review those amendments in addition to the unamended model code.
You can find a copy of the model code here.
You can find information about amendments to the model code
here.
Auto Search - beta:
2021 IRC(New Castle, CO 15.10.040 - International Residential Code Commentary.)
...The Commentary to the International Residential Code, 2021 Edition, published by the
International Code Council, 4051 West Flossmoor Road, Country Club Road, Illinois
60478-5795 is hereby adopted as an enforcement and interpretive guide. The building
official, or any authorized representative, shall have the discretion to apply the
contents...
Drip Edge
Drip Edge: yes
Ice Barrier
Are ice barriers required for New Castle ? Yes
Citation: New Castle, CO Muni. Code § 15.10.020.
Municipal Code
https://library.municode.com/co/new_castle/codes/code_of_ordinances?nodeId=TIT15BUCO_CH15.10INRECO_15.10.020AMComments:
TABLE 301.2(1) shall provide as follows:
GROUND SNOW LOAD |
WIND SPEED (mph) |
SEISMIC DESIGN CATEGORY |
SUBJECT TO DAMAGE FROM |
WINTER DESIGN TEMP |
ICE SHIELD UNDERLAYMENT REQUIRED |
FLOOD HAZARDS |
AIR FREEZING INDEX |
MEAN ANNUAL TEMPT |
WEATHERING |
FROST LINE DEPTH |
TERMITE |
DECAY |
57 PSF |
90 mph |
C |
Severe |
36" |
Slight to moderate |
Slight |
-2 F |
Yes |
Yes/10-15-85 |
2500 |
48 F |
Comments
New Castle, CO adopts the International Residential Code, 2015 edition, including Appendices H, J, and S. New Castle, CO Muni. Code § 15.10.010 (adopted) with amendments at § 15.10.020.
Existing Buildings
Existing buildings, meaning buildings that were built in accordance to code at the time of
construction, typically merit extra consideration in a current updated code.
Refer to Appendix J of the adopted 2015 IRC.
Commercial Building Code
New Castle adopted the 2015 IBC, locally. Note that adoptions usually come with amendments. So, it is important to review those amendments in addition to the unamended model code.
You can find a copy of the code
here.You can find information about amendments to the model code
here.
Auto Search - beta:
2015 IBC(New Castle, CO 15.08.040 - International Building Code Commentary.)
...The Commentary to the International Building Code, 2015 Edition, published by the
International Code Council, 4051 West Flossmoor Road, Country Club Road, Illinois
60478-5795 is hereby adopted as an enforcement and interpretive guide. The building
official, or any authorized representative, shall have the discretion to apply the
contents of...
Comments
New Castle, CO adopts the International Building Code, 2015 edition, including Appendices B, G, I, and J. New Castle, CO Muni. Code § 15.08.010 (adopted) with amendments at § 15.08.020.
Existing Buildings
New Castle, CO adopts the International Existing Building Code, 2015 edition, including all appendices. New Castle, CO Muni. Code § 15.18.010 (adopted) with amendments at § 15.18.020.
Other Building Codes
New Castle, CO also adopts the following codes:
- The International Mechanical Code, 2015 edition, including appendices. New Castle, CO Muni. Code § 15.12.010 (adopted) with amendments at § 15.12.020.
- The International Fuel Gas Code, 2015 edition, including appendices. New Castle, CO Muni. Code § 15.14.010 (adopted) with amendments at § 15.14.020.
- The International Plumbing Code, 2015 edition, including appendices. New Castle, CO Muni. Code § 15.16.010 (adopted) with amendments at § 15.16.020.
- The International Energy Conservation Code, 2009 edition. New Castle, CO Muni. Code § 15.22.010 (adopted) with amendments at § 15.22.030.
- The International Fire Code, 2015 edition, including all appendices. New Castle, CO Muni. Code § 15.24.010 (adopted) with amendments at § 15.24.020.
- The National Electrical Code (NFPA-70), edition that is adopted and enforced by the State of Colorado Electrical Board, including all appendices. New Castle, CO Muni. Code § 15.28.010 (adopted).