Updated : 04/22/2024
Overview
Hiawatha, IA has adopted the 2018 International Codes, with amendments, including the 2018 IRC and IBC. Hiawatha, IA Muni. Codes § 155.01 (adoptions) and § 155.02 through § 155.21 (amendments).
Helpful resources for Hiawatha, Iowa include the following.
Residential Building Code
Iowa adopted a model state residential code but it is not in force unless adopted locally.See PLRB,
Iowa Building Codes for more information on state level codes.
Hiawatha adopted the 2018 IRC, locally. Note that adoptions usually come with amendments. So, it is important to review those amendments in addition to the unamended model code.
You can find a copy of the model code here.
You can find information about amendments to the model code
here.
Auto Search - beta:
2015 IRC with Iowa amendments(Hiawatha, IA 155.01 INTERNATIONAL BUILDING CODE ADOPTED.)
...Except as hereinafter added to, deleted, modified or amended, there is hereby adopted as the Building Code of the City that certain Building Code known as the International Building Code , 2021 Edition including Appendix N: Replicable Buildings, and International Residential Code , 2021 Edition Chapters 2 through 10, including Appendix AF: Radon Control Methods and Appendix AQ: Tiny Houses....
Drip Edge
Drip Edge: yes
Ice Barrier
Are ice barriers required for Hiawatha ? Yes
Citation: § 155.10
Municipal Code
https://library.amlegal.com/nxt/gateway.dll/Iowa/hiawatha_ia/codeofordinancesofthecityofhiawathaiowa/chapter155buildingcode?f=templates$fn=default.htm$3.0$vid=amlegal:hiawatha_ia$anc=JD_155.10Comments:
Ground Snow Load
|
Wind Speed MPH
|
Seismic Design Category
|
Subject to Damage From:
|
Winter Design Temp
|
Ice Shield Under- Layment Required
|
Flood Hazards
|
Air Freezing Index
|
Mean Annual Temp
|
Weathering
|
Frost Line Depth
|
Termite
|
Decay
|
NFIP Adoption
|
FIRM Maps
|
30 PSF
|
115
|
A
|
Severe
|
42"
|
Moderate-Heavy
|
Slight- Moderate
|
-5 F
|
Yes
|
1982
|
4/5/10
|
1784
|
48.9
|
Comments
Hiawatha, IA has adopted the 2018 IRC, Chapters 1 through 10, including Appendix F: Passive Radon Gas Controls Methods and Appendix Q: Tiny Houses. Hiawatha, IA Muni. Code § 155.01.
Commercial Building Code
Hiawatha adopted the 2018 IBC, locally. Note that adoptions usually come with amendments. So, it is important to review those amendments in addition to the unamended model code.
You can find a copy of the code
here.You can find information about amendments to the model code
here.
Auto Search - beta:
2015 IBC with Iowa amendments(Hiawatha, IA Municipal Code)
...Adoption not found...
Comments
Hiawatha, IA has adopted the 2018 IBC including appendix N: Replicable Buildings. Hiawatha, IA Muni. Code § 155.01.
Existing Buildings
Hiawatha, IA did not adopt the IEBC, therefore Chapter 34 of the IBC would apply.
Other Building Codes
Hiawatha, IA also adopted the following codes:
Latest State of Iowa Plumbing Code. Hiawatha, IA Muni. Codes § 156.01 (adoption) and § 156.02 (amendments). Link to State of Iowa Building Codes.
2017 National Electrical Code (NFPA 70). Hiawatha, IA Muni. Codes § 157.01 (adoption) and § 157.02 (amendments).
2019 International Mechanical Code. Hiawatha, IA Muni. Codes § 158.01 (adoption) and § 158.02 (amendments).
2018 International Fire Code. Hiawatha, IA Muni. Codes § 160.02 (adoption) and § 160.04 (amendments).
2018 International Property Maintenance Code. Hiawatha, IA Muni. Codes § 164.02 (adoption) and § 164.03 (amendments).