Home / Building Codes / Texas / Burleson

Burleson, Texas Building Codes

Updated : 04/22/2024

Overview

Burleson, Texas, adopted the 2021 International Residential Code. Burleson, TX, Muni. Code § 10-171 (adoption) and Burleson, TX, Buildings and Regulations, Ordinance No. 2023-02 (2023)(amendments). Note that the municipal code may not be up-to-date but the ordinance includes the adoption of the 2021 IRC. Burleson, Texas, adopted the 2021 International Building Code. Burleson, TX, Muni. Code § 10-141 (adoption) and Burleson, TX, Buildings and Regulations, Ordinance No. 2023-02 (2023)(amendments). Note that the municipal code may not be up-to-date but the ordinance includes the adoption of the 2021 IBC. Burleson, Texas, adopted the 2021 International Existing Building Code. Burleson, TX, Muni. Code § 10-491 (adoption) and Burleson, TX, Buildings and Regulations, Ordinance No. 2023-02 (2023)(amendments). Note that the municipal code may not be up-to-date but the ordinance includes the adoption of the 2021 IEBC. 

Helpful resources for Burleson, Texas include the following.

Residential Building Code

Texas adopted a model state residential code but it is not in force unless adopted locally.See PLRB, Texas Building Codes for more information on state level codes.

Burleson adopted the 2021 IRC, locally. Note that adoptions usually come with amendments. So, it is important to review those amendments in addition to the unamended model code.

You can find a copy of the model code here.

You can find information about amendments to the model code here.

Auto Search - beta:

See Gen.code(City of Burleson , TX Ch 10 Art IV INTERNATIONAL RESIDENTIAL CODE)

...INTERNATIONAL RESIDENTIAL CODE...

Drip Edge

Drip Edge: yes

Ice Barrier

Are ice barriers required for Burleson ? No
Citation: Burleson, TX, Muni. Code Sec.10-172
Comments:

The adoption of the residential code included an amendment stating that ice barrier underlayment is not required at the eaves.

Ground Snow Load Wind Speed (mph) Topographic Effects Seismic Design Category Damage from Weathering Damange from Frost Line Depth
5lb/ft² 90 (3-sec-gust)/76 fastest mile No A moderate 6"

 

Damage from Termite Winter Design Temp Ice Barrier Underlayment Required Flood Hazards Air Freezing Index Mean Annual Temp
very heavy 22ºF No local code 150 64.9ºF

Burleson, TX, Buildings and Regulations, Ordinance No. 2023-02 (2023). 

Comments

Burleson, Texas, adopted the 2021 International Residential Code. Burleson, TX, Muni. Code § 10-171 (adoption) and Burleson, TX, Buildings and Regulations, Ordinance No. 2023-02 (2023)(amendments). Note that the municipal code may not be up-to-date but the ordinance includes the adoption of the 2021 IRC.

The city of Burleson, TX amended some roofing provisions:

Section R902.1; Amend and add exception #4 to read as follows:

R902.1 Roofing covering materials. Roofs shall be covered with materials as set forth in Sections R904 and R905. Class A, B, or C roofing shall be installed in areas designated by law as requiring their use or when the edge of the roof is less than 3 feet from a lot line. {remainder unchanged}

Exceptions:

4. Non-classified roof coverings shall be permitted on one-story detached accessory structures used as tool and storage sheds, playhouses and similar uses, provided the floor area does not exceed (area defined by jurisdiction).

Section R905.7 amend to read as follows:

R905.7 Wood shingles. The installation of wood shingles in new construction is prohibited.

Section R905.8 amend to read as follows:

R905.8 Wood shakes. The installation of wood shakes in new construction is prohibited.

Section R907.1 add a sentence as follows:

R907.1 General. All individual replacement shingles or shakes shall comply with Section R902.1.

Burleson, TX, Buildings and Regulations, Ordinance No. 2023-02 (2023).

Existing Buildings

Existing buildings, meaning buildings that were built in accordance to code at the time of construction, typically merit extra consideration in a current updated code.

No adoption of Appendix J was found in the municipal code or city ordinances.

Burleson, Texas, adopted the 2021 International Existing Building Code. Burleson, TX, Muni. Code § 10-491 (adoption) and Burleson, TX, Buildings and Regulations, Ordinance No. 2023-02 (2023)(amendments). Note that the municipal code may not be up-to-date but the ordinance includes the adoption of the 2021 IEBC. 

Commercial Building Code

Burleson adopted the 2021 IBC, locally. Note that adoptions usually come with amendments. So, it is important to review those amendments in addition to the unamended model code.

You can find a copy of the code here.You can find information about amendments to the model code here.

Auto Search - beta:

. See Gen.code(City of Burleson , TX Municipal Code)

...Adoption not found...

Comments

Burleson, Texas, adopted the 2021 International Building Code. Burleson, TX, Muni. Code § 10-141 (adoption) and Burleson, TX, Buildings and Regulations, Ordinance No. 2023-02 (2023)(amendments). Note that the municipal code may not be up-to-date but the ordinance includes the adoption of the 2021 IBC. 

Existing Buildings

Burleson, Texas, adopted the 2021 International Existing Building Code. Burleson, TX, Muni. Code § 10-491 (adoption) and Burleson, TX, Buildings and Regulations, Ordinance No. 2023-02 (2023)(amendments). Note that the municipal code may not be up-to-date but the ordinance includes the adoption of the 2021 IEBC. 

Other Building Codes

Burleson, Texas, adopted the 2015 International Property Maintenance Code (IPMC). Burleson, TX, Muni. Code § 10-291 (adoption) and § 10-292 (amendments). Note that the municipal code may not be up-to-date.

Burleson, Texas, adopted the 2020 National Electrical Code (NEC). Burleson, TX, Muni. Code § 10-201 (adoption), § 10-202 (amendments), and Burleson, TX, Buildings and Regulations, Ordinance No. 2023-02 (2023). Note that the municipal code may not be up-to-date but the ordinance includes the adoption of the 2021 NEC. 

Burleson, Texas, adopted the 2021 International Energy Conservation Code (IECC). Burleson, TX, Muni. Code § 10-351 (adoption), § 10-352 (amendments), and Burleson, TX, Buildings and Regulations, Ordinance No. 2023-02 (2023). Note that the municipal code may not be up-to-date but the ordinance includes the adoption of the 2021 IECC. 

Burleson, Texas, adopted the 2021 International Fire Code (IFC). Burleson, TX, Muni. Code § 38-191 (adoption) and § 38-192 (amendments).

Burleson, Texas, adopted the 2021 International Fuel Gas Code (IFGC). Burleson, TX, Muni. Code § 10-321 (adoption), § 10-322 (amendments), and Burleson, TX, Buildings and Regulations, Ordinance No. 2023-02 (2023). Note that the municipal code may not be up-to-date but the ordinance includes the adoption of the 2021 IFGC. 

Burleson, Texas, adopted the 2021 International Mechanical Code (IMC). Burleson, TX, Muni. Code § 10-261 (adoption), § 10-262 (amendments), and Burleson, TX, Buildings and Regulations, Ordinance No. 2023-02 (2023). Note that the municipal code may not be up-to-date but the ordinance includes the adoption of the 2021 IMC. 

Burleson, Texas, adopted the 2021 International Plumbing Code (IPC). Burleson, TX, Muni. Code § 10-231 (adoption), § 10-232 (amendments), and Burleson, TX, Buildings and Regulations, Ordinance No. 2023-02 (2023). Note that the municipal code may not be up-to-date but the ordinance includes the adoption of the 2021 IPC.