Buffalo, Wyoming Building Codes

Updated : 04/22/2024

Overview

Buffalo, Wyoming, adopted the 2018 International Residential Code, including Appendix E, M, H, and Q, with amendments. Buffalo, WY Muni. Code § 5.1.3 (adoption and amendments). Buffalo, Wyoming, adopted the 2018 International Building Code, including Appendix A, B, and I, with amendments. Buffalo, WY Muni. Code § 5.1.2 (adoption and amendments). Buffalo, Wyoming, adopted the 2018 International Existing Building Code, including Resource A. Buffalo, WY Muni. Code § 5.1.7 (adoption and amendments).

Helpful resources for Buffalo, Wyoming include the following.

Residential Building Code

Wyoming has yet to adopt a statewide residential code. Local laws will control.See PLRB, Wyoming Building Codes for more information on state level codes.

Buffalo adopted the 2018 IRC, locally. Note that adoptions usually come with amendments. So, it is important to review those amendments in addition to the unamended model code.

You can find a copy of the model code here.

You can find information about amendments to the model code here.

Auto Search - beta:

No results were located with the automated search.

Drip Edge

Drip Edge: yes

Ice Barrier

Are ice barriers required for Buffalo ? Yes
Citation: https://www.cityofbuffalowy.com/pview.aspx?id=56152&catid=510
Comments:

The adoption of the residential code included an amendment stating that ice barrier underlayment is required at the eaves.

TABLE R301.2(1) CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA
Ground Snow Load 30 lbs per sq ft
Wind Speed 115 MPH
Exposure C 
Seismic Design Category C SUBJECT TO DAMAGE FROM: Weathering Severe Frost Line
Depth 42 inches
Termite Slight to moderate
Decay None to slight
Winter Design Temp -7 F
Ice Shield Underlayment Required Yes
Flood Hazard 4/1/1978
Air Freezing Index 1704
Mean Annual Temp 44.8 F

Footnotes:

1. IRC Figure R301.2(5A), page 46
2. IRC Figure R301.2(4) page 45
3. IRC Figure R301.2.2 page 38
4. IRC Figure R301.2(3) page 43
5. Frost line depth was determined in 1976 using local conditions.
6. IRC Figure R301.2(6) page 48
7. IRC Figure R301.2(7) page 50
8. Winter Design Temperature is determined by ASHRE and local conditions as the temperature will be above -7 degrees 97%.
9. Local weather data indicates the average daily temperature for January is 22F. 10. The Air Freezing Index was obtained using the National Climatic Data Center Mean Annual Temperature obtained from the National Data Center. Section R313.2 is hereby deleted.

Buffalo, WY, Muni.Code § 5.1.3

Comments

Buffalo, Wyoming, adopted the 2018 International Residential Code, including Appendix E, M, H, and Q. Buffalo, WY Muni. Code § 5.1.3 (adoption and amendments).

Existing Buildings

Existing buildings, meaning buildings that were built in accordance to code at the time of construction, typically merit extra consideration in a current updated code.

Buffalo, Wyoming, did not expressly adopt Appendix AJ of the IRC. However, Buffalo, Wyoming, adopted the 2018 International Existing Building Code, Including Resource A. Buffalo, WY Muni. Code § 5.1.7 (adoption and amendments).

An amendment to the adopted residential code states:

R102.7 Existing Structures. "The legal occupancy of any structure existing on the date of the adoption of this code shall be permitted to continue, without change, except as is specifically covered in this code, or the International Fire Code, or as is deemed necessary by the building official for the general safety and welfare of the occupants and the public." Buffalo, WY Muni.Code § 5.1.7 (Adoption and amendments).

Buffalo, WY Muni. Code § 5.1.7 (adoption and amendments).

Commercial Building Code

Buffalo adopted the 2018 IBC, locally. Note that adoptions usually come with amendments. So, it is important to review those amendments in addition to the unamended model code.

You can find a copy of the code here.You can find information about amendments to the model code here.

Auto Search - beta:

No results were located with the automated search.

Comments

Buffalo adopted the 2018 International Building Code, Appendix A, B, and I. Buffalo, WY Muni. Code § 5.1.2 (adoption and amendments).

Existing Buildings

Buffalo adopted the 2018 International Existing Building Code, including Resource A. Buffalo, WY Muni. Code § 5.1.7 (adoption and amendments).

Other Building Codes

Buffalo adopted the 2018 International Plumbing Code. Buffalo, WY Muni. Code § 5.1.4 (adoption and amendments).

Buffalo adopted the 2018 International Mechanical Code. Buffalo, WY Muni. Code § 5.1.5 (adoption and amendments).

Buffalo adopted the 2018 International Fuel Gas Code. Buffalo, WY Muni. Code § 5.1.6 (adoption and amendments).

Buffalo adopted the Uniform Code For The Abatement of Dangerous Buildings. Buffalo, WY Muni. Code § 5.1.8 (adoption and amendments).

Buffalo adopted City-Specific Codes. Buffalo, WY Muni. Code § 5.1.9 (adoption and amendments).

Buffalo adopted the Fence Code. Buffalo, WY Muni. Code § 5.1.10 (adoption and amendments).

Buffalo adopted Solar Rights. Buffalo, WY Muni. Code § 5.1.11 (adoption and amendments).