Bar Nunn, Wyoming Building Codes

Updated : 04/22/2024

Overview

Bar Nunn, Wyoming, adopted the "2003 or current" International Residential Code (IRC). Bar Nunn, Wyo. Muni. Code § 7-1-1-5 (adoption). Bar Nunn, Wyoming, adopted the "2003 or current" International Building Code (IBC). Bar Nunn, Wyo. Muni. Code § 7-1-1-1 (adoption). Note "Current" likely refers to the 2021 edition and is most likely enforceable.

According to Donna Damori, the City of Mills, Wyoming provides the inspections for the Town of Bar Nunn. Inspector, Kevin O’Hearn can be reached at 307-234-6679. (08/30/2023).

Helpful resources for Bar Nunn, Wyoming include the following.

Residential Building Code

Wyoming has yet to adopt a statewide residential code. Local laws will control.See PLRB, Wyoming Building Codes for more information on state level codes.

Bar Nunn adopted the 2021 IRC, locally. Note that adoptions usually come with amendments. So, it is important to review those amendments in addition to the unamended model code.

You can find a copy of the model code here.

You can find information about amendments to the model code here.

Auto Search - beta:

IRC, Fire and Life Safety (2012 IBC)(Bar Nunn, WY 7-1-1-5: RESIDENTIAL CODE:)

...life, health, property and public welfare, the suggested Code known as the International Residential Code, 2003 or current edition. One copy of this c...

2003 IRC(Bar Nunn, WY 7-1-1-5: RESIDENTIAL CODE:)

...7-1-1-5: RESIDENTIAL CODE: A. Adopted: There is hereby adopted by the town of Bar Nunn for the purpose of prescribing regulations to safeguard life, health, property and public welfare, the suggested code known as the international residential code, 2003 or current edition. One copy of this code shall be kept on file at Bar Nunn Town Hall....

Drip Edge

Drip Edge: yes

Ice Barrier

Are ice barriers required for Bar Nunn ? Unclear
Comments:

No amendment to Table R301.2(1) was located. Therefore, it is unclear if ice barrier underlayment is required.

Comments

Bar Nunn, Wyoming, adopted the "2003 or current" International Residential Code (IRC). Bar Nunn, Wyo. Muni. Code § 7-1-1-5 (adoption and amendments). Note: "Current" likely refers to the 2021 edition and is likely enforceable.

Existing Buildings

Existing buildings, meaning buildings that were built in accordance to code at the time of construction, typically merit extra consideration in a current updated code.

Barr Nunn, Wyoming, did not expressly adopt Appendix AJ of the IRC. Furthermore, no local adoption of the International Existing Building Code was located.

Commercial Building Code

Bar Nunn adopted the 2021 IBC, locally. Note that adoptions usually come with amendments. So, it is important to review those amendments in addition to the unamended model code.

You can find a copy of the code here.You can find information about amendments to the model code here.

Auto Search - beta:

See Amlegal(Bar Nunn, WY CHAPTER 1 BUILDING CODES)

...TITLE 7 BUILDING REGULATIONS CHAPTER 1 BUILDING CODES SECTION: 7-1-1 : Building Codes 7-1-1-1 : Building Code 7-1-1-2 : Fire Code 7-1-1-3 : Plumbing Code 7-1-1-4 : Mechanical Code 7-1-1-5 : Residential Code 7-1-1-6 : Sign Code 7-1-1-7 : Code For The Abatement Of Dangerous Buildings 7-1-1-8 : Electrical Code 7-1-2 : Building And Demolition Permit Fees 7-1-3 : Fence Requirements At Excavations 7-1-4 : Penalty...

See sterling(Bar Nunn, WY Municipal Code)

...Adoption not found...

Comments

Bar Nunn, Wyoming, adopted the "2003 or current" International Building Code (IBC). Bar Nunn, Wyo. Muni. Code § 7-1-1-1 (adoption and amendments). Note: "Current" likely refers to the 2021 edition and is most likely enforceable.

Existing Buildings

No local adoption of the International Existing Building Code was located; However, the adopted IBC references the IEBC in 102.6 "Existing Structures" and the state adopted the 2021 IEBC as a state code.

Other Building Codes

Bur Nunn, Wyoming, adopted the 2006 edition of the International Fire Code, including appendices A through G. Bar Nunn, Wyo. Muni. Code § 7-1-1-2 (adoption and amendments).

Bur Nunn, Wyoming, adopted the "current" Uniform Plumbing Code, Bar Nunn, Wyo. Muni. Code § 7-1-1-3 (adoption and amendments).

Bur Nunn, Wyoming, adopted the "2003 or current" International Mechanical Code. Bar Nunn, Wyo. Muni. Code § 7-1-1-4 (adoption and amendments).

Bur Nunn, Wyoming, adopted the "current" Uniform Sign Code. Bar Nunn, Wyo. Muni. Code § 7-1-1-6 (adoption and amendments).

Bur Nunn, Wyoming, adopted the "current" Uniform Code for the Abatement of Dangerous Buildings, Bar Nunn, Wyo. Muni. Code § 7-1-1-7 (adoption and amendments).

Bur Nunn, Wyoming, adopted the "2002 or the current" National Electrical Code. Bar Nunn, Wyo. Muni. Code § 7-1-1-8 (adoption and amendments).

Note: "Current" likely refers to the 2021 edition and is most likely enforceable.