Updated : 04/22/2024
Overview
Ely, IA has adopted the 2015 International Codes, with amendments, including the 2015 IRC and IBC. Ely, IA Muni. Codes § 155.01 (adoption) and § 155.02 (amendments).
Helpful resources for Ely, Iowa include the following.
Residential Building Code
Iowa adopted a model state residential code but it is not in force unless adopted locally.See PLRB,
Iowa Building Codes for more information on state level codes.
Ely adopted the 2015 IRC, locally. Note that adoptions usually come with amendments. So, it is important to review those amendments in addition to the unamended model code.
You can find a copy of the model code here.
You can find information about amendments to the model code
here.
Auto Search - beta:
2015 IRC with Iowa amendments(Ely, IA 155.01 INTERNATIONAL BUILDING CODES.)
...Except as hereinafter added to, deleted, modified or amended, there is hereby adopted as the Construction Regulations of the City the certain codes known as the International Building Code, 2015 Edition, and International Residential Code, 2015 Edition, including Appendix F titled Radon Control Methods as prepared and edited by the International Code Council, Inc. and the provisions of said Codes shall be controlling in the construction of single-family and two-family homes within the incorporated limits of the City and shall be known as the Ely Construction Regulations....
Drip Edge
Drip Edge: yes
Ice Barrier
Are ice barriers required for Ely ? Yes
Citation: § 155.02
Municipal Code
https://library.amlegal.com/nxt/gateway.dll/Iowa/ely_ia/codeofordinancesofthecityofelyiowa/chapter155buildingcodes?f=templates$fn=default.htm$3.0$vid=amlegal:ely_ia$anc=JD_155.02Comments:
Table R301.2 (1)
Climatic and Geographic Design Criteria
Ground Snow Load
|
WIND DESIGN
|
Seismic Design Category
|
Subject to Damage From
|
Speed (mph)
|
Topographic effects
|
Special Wind Region
|
Wind Borne Debris Zone
|
Weathering
|
Frost Line Depth
|
Termite
|
30 PSF
|
115
|
No
|
No
|
No
|
A
|
Severe
|
42 inches
|
Moderate – Heavy
|
Winter Design Temp
|
Ice Barrier Underlayment
Required
|
Flood Hazards
|
Air Freezing Index
|
Mean Annual Temp
|
|
|
NFIP Adoption
|
FIRM Maps
|
|
|
-5°F
|
Yes
|
May 18, 1993
|
April 5, 2010
|
2500
|
48.9
|
Government Officials
Last Name |
First Name |
Title |
E-mail |
Phone |
Note |
McGuire |
Mary |
Building Official |
inspector@elyiowa.com |
319/848-4103 |
|
Comments
Ely, IA has adopted the 2015 IRC including appendix F. Ely, IA Muni. Code $ 155.01
R313.1 Townhouse automatic fire sprinkler systems. An automatic residential fire sprinkler system shall be installed throughout all attached townhouse dwelling units when any of the following conditions exist:
1. The townhouses are constructed in a group of more than four attached units.
2. Any individual townhouse dwelling unit of a structure with four or fewer attached townhouses has a floor area greater than 4,000 square feet on any one story or greater than 8,000 square feet of total floor area for all stories, excluding non-habitable areas separated from the rest of the building by a minimum of one-hour fire-resistive construction and containing smoke or heat detection interconnected with the dwelling unit smoke detectors.
Exception: An automatic residential fire sprinkler system shall not be required when additions or alterations are made to existing townhouses that do not have an automatic residential fire sprinkler system installed.
R313.1.1 Design and installation. Automatic residential fire sprinkler systems for townhouses shall be designed and installed in accordance with NFPA 130 or Section P2904.
R313.2 One- and two-family dwellings automatic fire sprinkler systems. Automatic residential fire sprinkler systems shall be installed in one- and two-family dwellings when the following condition exists:
1. The one-or two-family dwelling has a floor area greater than 4,000 square feet on any one story or greater than 8,000 square feet of total floor area for all stories, excluding non-habitable areas separated from the rest of the building by a minimum of one-hour fire-resistive construction and containing smoke or heat detection interconnected with the dwelling unit smoke detectors.
Exception: An automatic residential fire sprinkler system shall not be required when additions or alterations are made to existing one- and two family dwellings that do not have an automatic residential fire sprinkler system installed.
R313.2.1 Design and installation. Automatic residential fire sprinkler systems for one-and two-family dwellings shall be designed and installed in accordance with NFPA 130 or Section P2904.
Ely, IA Muni. Code § 155.02 (amendments).
Commercial Building Code
Ely adopted the 2015 IBC, locally. Note that adoptions usually come with amendments. So, it is important to review those amendments in addition to the unamended model code.
You can find a copy of the code
here.You can find information about amendments to the model code
here.
Auto Search - beta:
2015 IBC with Iowa amendments(Ely, IA Municipal Code)
...Adoption not found...
Existing Buildings
Ely, IA did not adopt the IEBC, therefore Chapter 34 of the IBC would apply.
Other Building Codes
Ely, IA also adopted the following codes:
2006 ICC Electrical Code – Administrative Provisions. Ely, IA Muni. Codes § 156.01 (adoption) and § 156.02 (amendments).
2014 National Electrical Code (NFPA 70) Ely, IA Muni. Codes § 156.01 (adoption) and § 156.03 (amendments).