The city of Beaver Dam, Wi. adopted the Uniform Dwelling Code, SPS chs. 320–325; the city also expressly adopted the Wisconsin Commercial Building Code, SPS chs. 361–366. Beaver Dam, Wi. Mun. Code § 4-40 (accessed 3/31/2015).
Helpful resources for Beaver Dam, Wisconsin include the following.
Residential Building Code
Wisconsin adopted a statewide mandatory residential code that will control. Authority for local amendments will be limited.See PLRB,
Wisconsin Building Codes for more information on state level codes.
Beaver Dam adopted the Wisconsin Uniform Residential CodeYou can find a copy of the code here.You can find information about amendments to the model code here.
Auto Search - beta:
Wisconsin Uniform Dwelling Code(Beaver Dam, WI Municipal Code)
...Adoption not found...
Drip Edge
Drip Edge: No
Ice Barrier
Comments
The city of Beaver Dam, Wi. adopted the Uniform Dwelling Code, SPS chs. 320–325. Beaver Dam, Wi. Mun. Code § 4-40 (accessed 3/31/2015). This code regulates new construction and applies to the code that is in effect at the time of permit application.
Existing Buildings
Existing buildings, meaning buildings that were built in accordance to code at the time of
construction, typically merit extra consideration in a current updated code.
The city of Beaver Dam, Wi. enforces a locally adopted maintenance code entitled the Basic Housing Property Maintenance Regulations. Beaver Dam, Wi. Mun. Code, Chapter 14, Art. III – Housing (accessed 4/1/2015).
Commercial Building Code
Beaver Dam adopted the 1996 BOCA National Building CodeYou can find a copy of the code here.You can find information about amendments to the model code here.
Auto Search - beta:
Wisconsin Commercial Bldg. Code (2015 IBC)(Beaver Dam, WI Municipal Code)
...Adoption not found...
Comments
The city of Beaver Dam, Wi. the Wisconsin Commercial Building Code, SPS chs. 361–366. Beaver Dam, Wi. Mun. Code § 4-40(1) (accessed 3/31/2015). Additional local provisions are included in Ch. 14, Art II, Div. – Building Code.
The city of Beaver Dam, Wi. provides certain grandfathered ordinances (variances to the CBC). An ordinance that is grandfathered has passed the requirements laid out by the Legislature in Wisconsin Statute §101.02(7r)(b). The grandfathered ordinances are listed below:
Sec. 30-1
(4) State and federal codes adopted. In addition to the regulations standards and procedures hereinafter set forth, compliance shall be made with the provisions of the DSPS and the most current state adopted edition of the NFPA (NFPA Chapters: NFPA 1, NFPA 101, SPS 314, and International Building Code, (IBC)) as it relates to fire prevention.
Sec. 30-9
Regulation for fire department connections (FDC) fire sprinklers, automatic fire suppression systems, and standpipes (NFPA 24, 13, 14, 15, 16, 13R and NFPA 1(13)).
(1) Where a FDC for each standpipe, automatic fire suppression system, or fire sprinkler system is in place, there shall be a fire hydrant within a distance determined by the AHJ.
(2) Fire department connections shall be located not less than 18 inches or more than 48 inches above the level of the adjoining ground, sidewalk, or grade surface.
(3) Time of compliance of new and existing establishments. All new establishments subject to this section shall comply therewith before a permit of occupancy is granted by the building inspector and fire chief or designee. All existing establishments built prior to January 1, 2005, are exempt, except that any new additions to previously exempted buildings must comply with current codes.
(4) FDC shall be five-inch Storz connection.
(PDF version here)
Existing Buildings
The 2009 IEBC is made part of the Commercial Building Code, subject to the modifications specified in the Wis. Adm. Code § SPS 366.
Other Building Codes
The Wisconsin Electrical Code § SPS 316 (Based on the National Electrical Code, NFPA 70, 2011 edition). Beaver Dam, Wi. Mun. Code § 14-111 (electrical regulations adopted) (accessed 4/1/2015).
The Wisconsin Plumbing Code Plumbing § SPS 380-387. Beaver Dam, Wi. Mun. Code § 14-81 (plumbing regulations adopted) (accessed 4/1/2015).
The city of Beaver Dam, Wi. enforces the most current state adopted edition of the NFPA (NFPA Chapters: NFPA 1, NFPA 101, SPS 314, and International Building Code, (IBC)) as it relates to fire prevention. Beaver Dam, Wi. Mun. Code § 30-1(4) (fire prevention and protection – general provisions) (accessed 4/1/2015).
The International Energy Conservation Code, 2009 edition. Subject to modifications specified in § SPS 363.
The International Mechanical Code, 2009 edition. Subject to modifications specified in § SPS 364.
The International Fuel Gas Code, 2009 edition. Subject to modifications specified in § SPS 365.